Sec. 80.761 Conversion graphs.
The following graphs must be employed where conversion from one to
the other of the indicated types of units is required.
(a) Graph 1. To convert effective radiated power in watts to dBk or
to dBW, find the power in watts on the horizontal axis. Move vertically
along the line representing the power to the diagonal line. Move
horizontally from the diagonal to the right side to read dBW and to the
left to read dBk.
(b) Graph 2. To convert microvolts across 50 ohms to received power
in dBW, find the signal in microvolts on the horizontal axis. Move
vertically to the diagonal line, then move right horizontally to read
dBW.
[[Page 122]]
[GRAPHIC] [TIFF OMITTED] TC02AP91.002
[[Page 123]]
[GRAPHIC] [TIFF OMITTED] TC02AP91.003
(c) Graph 3. To convert received power in dBW to field intensity in
dBu find the received power in dBW on the horizontal axis. Move
vertically to the diagonal line, then move right horizontally to read
dBu.
[[Page 124]]
[GRAPHIC] [TIFF OMITTED] TC02AP91.004