Goto Section: 17.209 | 17.213
FCC 17.211
Revised as of June 29, 2005
Goto Year:2004 |
2006
Sec. 15.211 Tunnel radio systems.
An intentional radiator utilized as part of a tunnel radio system may
operate on any frequency provided it meets all of the following
conditions:
(a) Operation of a tunnel radio system (intentional radiator and all
connecting wires) shall be contained solely within a tunnel, mine or
other structure that provides attenuation to the radiated signal due
to the presence of naturally surrounding earth and/or water.
(b) Any intentional or unintentional radiator external to the tunnel,
mine or other structure, as described in paragraph (a) of this
section, shall be subject to the other applicable regulations
contained within this part.
(c) The total electromagnetic field from a tunnel radio system on any
frequency or frequencies appearing outside of the tunnel, mine or
other structure described in paragraph (a) of this section, shall not
exceed the limits shown in Sec. 15.209 when measured at the specified
distance from the surrounding structure, including openings.
Particular attention shall be paid to the emissions from any opening
in the structure to the outside environment. When measurements are
made from the openings, the distances shown in Sec. 15.209 refer to the
distance from the plane of reference which fits the entire perimeter
of each above ground opening.
(d) The conducted limits in Sec. 15.207 apply to the radiofrequency
voltage on the public utility power lines outside of the tunnel.
Goto Section: 17.209 | 17.213
Goto Year: 2004 |
2006
CiteFind - See documents on FCC website that
cite this rule
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public