FCC 18.309 Revised as of October 1, 2005
Goto Year:2004 |
2006
Sec. 18.309 Frequency range of measurements.
(a) For field strength measurements:
-------------------------------------------------------------------------------
---------------------------------
Range of frequency
measurements
Frequency band in which device operates ---------------------------------------
---------------------------------
(MHz) Lowest frequency
Highest frequency
-------------------------------------------------------------------------------
---------------------------------
Below 1.705............................ Lowest frequency generated in the 3
0 MHz.
device, but not lower than 9 kHz.
1.705 to 30............................ Lowest frequency generated in the 4
00 MHz.
device, but not lower than 9 kHz.
30 to 500.............................. Lowest frequency generated in the T
enth harmonic or 1,000 MHz,
device or 25 MHz, whichever is
whichever is higher.
lower.
500 to 1,000........................... Lowest frequency generated in the T
enth harmonic.
device or 100 MHz, whichever is
lower.
Above 1,000............................ ......do........................... T
enth harmonic or highest
detectable emission.
-------------------------------------------------------------------------------
---------------------------------
(b) For conducted powerline measurements, the frequency range over which the
limits are specified will be scanned.
[ 50 FR 36070 , Sept. 5, 1985, as amended at 51 FR 17971 , May 16 1986]