Goto Section: 21.531 | 21.537
FCC 21.535
Revised as of May 5, 2005
Goto Year:2004 |
2006
Sec. 22.535 Effective radiated power limits.
The effective radiated power (ERP) of transmitters operating on the
channels listed in Sec. 22.531 must not exceed the limits in this section.
(a) Maximum ERP. The ERP must not exceed the applicable limits in this
paragraph under any circumstances.
------------------------------------------------------------------------
Maximum ERP
Frequency range (MHz) (Watts)
------------------------------------------------------------------------
35-36...................................................... 600
43-44...................................................... 500
152-159.................................................... 1400
931-932.................................................... 3500
------------------------------------------------------------------------
(b) Basic power limit. Except as provided in paragraph (d) of this
section, the ERP of transmitters on the VHF channels must not exceed
500 Watts.
(c) Height-power limit. Except as provided in paragraph (d) of this
section, the ERP of transmitters on the VHF channels must not exceed
the amount that would result in an average distance to the service
contour of 32.2 kilometers (20 miles). The average distance to the
service contour is calculated by taking the arithmetic mean of the
distances determined using the procedures specified in Sec. 22.537 for the
eight cardinal radial directions, excluding cardinal radial directions
for which 90% or more of the distance so calculated is over water.
(d) Encompassed interfering contour areas. Transmitters are exempt
from the basic power and height-power limits of this section if the
area within their interfering contours is totally encompassed by the
interfering contours of operating co-channel base transmitters
controlled by the same licensee. For the purpose of this paragraph,
operating transmitters are authorized transmitters that are providing
service to subscribers.
(e) Adjacent channel protection. The ERP of transmitters must not
exceed 500 Watts if they:
(1) Transmit on a channel in the 152-159 MHz frequency range and are
located less than 5 kilometers (3.1 miles) from any station licensed
in the Private Radio Services that receives on an adjacent channel;
or,
(2) Transmit on channel 158.10 or 158.70 MHz and are located less than
5 kilometers (3.1 miles) from any station licensed in the Public
Mobile Services that receives on either of the following adjacent
channels: 158.07 MHz or 158.67 MHz.
(f) Signal boosters. The effective radiated power of signal boosters
must not exceed 5 watts ERP under any normal operating condition.
[ 59 FR 59507 , Nov. 17, 1994, as amended at 61 FR 31051 , June 19, 1996]