Goto Section: 17.45 | 17.48 | Table of Contents

FCC 17.47
Revised as of October 1, 2006
Goto Year:2005 | 2007
Sec.  17.47   Inspection of antenna structure lights and associated control
equipment.

   The owner of any antenna structure which is registered with the Commission
   and has been assigned lighting specifications referenced in this part:

   (a)(1) Shall make an observation of the antenna structure's lights at least
   once each 24 hours either visually or by observing an automatic properly
   maintained indicator designed to register any failure of such lights, to
   insure  that  all such lights are functioning properly as required; or
   alternatively,

   (2) Shall provide and properly maintain an automatic alarm system designed
   to detect any failure of such lights and to provide indication of such
   failure to the owner.

   (b) Shall inspect at intervals not to exceed 3 months all automatic or
   mechanical control devices, indicators, and alarm systems associated with
   the antenna structure lighting to insure that such apparatus is functioning
   properly.

   [ 61 FR 4363 , Feb. 6, 1996]


Goto Section: 17.45 | 17.48

Goto Year: 2005 | 2007
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public