Goto Section: 90.633 | 90.637 | Table of Contents
FCC 90.635
Revised as of October 1, 2006
Goto Year:2005 |
2007
Sec. 90.635 Limitations on power and antenna height.
(a) The effective radiated power and antenna height for base stations may
not exceed 1 kilowatt (30 dBw) and 304 m. (1,000 ft.) above average terrain
(AAT), respectively, or the equivalent thereof as determined from the Table.
These are maximum values, and applicants will be required to justify power
levels and antenna heights requested.
(b) The maximum output power of the transmitter for mobile stations is 100
watts (20 dBw).
Table_Equivalent Power and Antenna Heights for Base Stations in the 851-
869 MHz and 935-940 MHz Bands Which Have a Requirement for a 32 km (20
mi) Service Area Radius
------------------------------------------------------------------------
Effective
radiated power
Antenna height (ATT) meters (feet) (watts)
\1,2,4\
------------------------------------------------------------------------
Above 1,372 (4,500)..................................... 65
Above 1,220 (4,000) to 1,372 (4,500).................... 70
Above 1,067 (3,500) to 1,220 (4,000).................... 75
Above 915 (3,000) to 1,067 (3,500)...................... 100
Above 763 (2,500) to 915 (3,000)........................ 140
Above 610 (2,000) to 763 (2,500)........................ 200
Above 458 (1,500) to 610 (2,000)........................ 350
Above 305 (1,000) to 458 (1,500)........................ 600
Up to 305 (1,000)....................................... \3\ 1,000
------------------------------------------------------------------------
\1\ Power is given in terms of effective radiated power (ERP).
\2\ Applicants in the Los Angeles, CA, area who demonstrate a need to
serve both the downtown and fringe areas will be permitted to utilize
an ERP of 1 kw at the following mountaintop sites: Santiago Park,
Sierra Peak, Mount Lukens, and Mount Wilson.
\3\ Stations with antennas below 305 m (1,000 ft) (AAT) will be
restricted to a maximum power of 1 kw (ERP).
\4\ Licensees in San Diego, CA, will be permitted to utilize an ERP of
500 watts at the following mountaintop sites: Palomar, Otay, Woodson
and Miguel.
[ 70 FR 61062 , Oct. 20, 2005]
Goto Section: 90.633 | 90.637
Goto Year: 2005 |
2007
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public