Goto Section: 15.507 | 15.510 | Table of Contents
FCC 15.509
Revised as of October 1, 2008
Goto Year:2007 |
2009
Sec. 15.509 Technical requirements for ground penetrating radars and wall
imaging systems.
(a) The UWB bandwidth of an imaging system operating under the provisions of
this section must be below 10.6 GHz.
(b) Operation under the provisions of this section is limited to GPRs and
wall imaging systems operated for purposes associated with law enforcement,
fire fighting, emergency rescue, scientific research, commercial mining, or
construction.
(1) Parties operating this equipment must be eligible for licensing under
the provisions of part 90 of this chapter.
(2) The operation of imaging systems under this section requires
coordination, as detailed in Sec. 15.525.
(c) A GPR that is designed to be operated while being hand held and a wall
imaging system shall contain a manually operated switch that causes the
transmitter to cease operation within 10 seconds of being released by the
operator. In lieu of a switch located on the imaging system, it is
permissible to operate an imaging system by remote control provided the
imaging system ceases transmission within 10 seconds of the remote switch
being released by the operator.
(d) The radiated emissions at or below 960 MHz from a device operating under
the provisions of this section shall not exceed the emission levels in
Sec. 15.209. The radiated emissions above 960 MHz from a device operating under
the provisions of this section shall not exceed the following average limits
when measured using a resolution bandwidth of 1 MHz:
Frequency in MHz EIRP in dBm
960–1610 –65.3
1610–1990 –53.3
1990–3100 –51.3
3100–10600 –41.3
Above 10600 –51.3
(e) In addition to the radiated emission limits specified in the table in
paragraph (d) of this section, UWB transmitters operating under the
provisions of this section shall not exceed the following average limits
when measured using a resolution bandwidth of no less than 1 kHz:
Frequency in MHz EIRP in dBm
1164–1240 –75.3
1559–1610 –75.3
(f) For UWB devices where the frequency at which the highest radiated
emission occurs, f[M], is above 960 MHz, there is a limit on the peak level
of the emissions contained within a 50 MHz bandwidth centered on f[M]. That
limit is 0 dBm EIRP. It is acceptable to employ a different resolution
bandwidth, and a correspondingly different peak emission limit, following
the procedures described in Sec. 15.521.
[ 68 FR 19749 , Apr. 22, 2003]
Goto Section: 15.507 | 15.510
Goto Year: 2007 |
2009
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public