Sec. 24.232 Power and antenna height limits.
Link to an amendment published at 73 FR 24183 , May 2, 2008.
(a) Base stations are limited to 1640 watts peak equivalent isotropically
radiated power (EIRP) with an antenna height up to 300 meters HAAT, except
as described in paragraph (b) below. See Sec. 24.53 for HAAT calculation method.
Base station antenna heights may exceed 300 meters with a corresponding
reduction in power; see Table 1 of this section. The service area boundary
limit and microwave protection criteria specified in Sec. Sec. 24.236 and 24.237
apply.
Table 1—Reduced Power for Base Station Antenna Heights Over 300 Meters
HAAT in meters Maximum EIRP watts
≤ 300 1640
≤ 500 1070
≤ 1000 490
≤ 1500 270
≤ 2000 160
(b) Base stations that are located in counties with population densities of
100 persons or fewer per square mile, based upon the most recently available
population statistics from the Bureau of the Census, are limited to 3280
watts peak equivalent isotropically radiated power (EIRP) with an antenna
height up to 300 meters HAAT; See Sec. 24.53 for HAAT calculation method. Base
station antenna heights may exceed 300 meters with a corresponding reduction
in power; see Table 2 of this section. The service area boundary limit and
microwave protection criteria specified in Sec. Sec. 24.236 and 24.237 apply.
Operation under this paragraph must be coordinated in advance with all PCS
licensees within 120 kilometers (75 miles) of the base station and is
limited to base stations located more than 120 kilometers (75 miles) from
the Canadian border and more than 75 kilometers (45 miles) from the Mexican
border.
Table 2—Reduced Power for Base Station Antenna Heights Over 300 Meters
HAAT in meters Maximum EIRP watts
≤ 300 3280
≤ 500 2140
≤ 1000 980
≤ 1500 540
≤ 2000 320
(c) Mobile/portable stations are limited to 2 watts EIRP peak power and the
equipment must employ means to limit the power to the minimum necessary for
successful communications.
(d) Peak transmit power must be measured over any interval of continuous
transmission using instrumentation calibrated in terms of an rms-equivalent
voltage. The measurement results shall be properly adjusted for any
instrument limitations, such as detector response times, limited resolution
bandwidth capability when compared to the emission bandwidth, sensitivity,
etc., so as to obtain a true peak measurement for the emission in question
over the full bandwidth of the channel.
[ 70 FR 61059 , Oct. 20, 2005]
Goto Section: 24.229 | 24.235
Goto Year: 2007 |
2009
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public