Goto Section: 76.613 | 76.616 | Table of Contents
FCC 76.614
Revised as of October 1, 2009
Goto Year:2008 |
2010
§ 76.614 Cable television system regular monitoring.
Cable television operators transmitting carriers in the frequency bands
108–137 and 225–400 MHz shall provide for a program of regular
monitoring for signal leakage by substantially covering the plant every
three months. The incorporation of this monitoring program into the
daily activities of existing service personnel in the discharge of
their normal duties will generally cover all portions of the system and
will therefore meet this requirement. Monitoring equipment and
procedures utilized by a cable operator shall be adequate to detect a
leakage source which produces a field strength in these bands of 20
uV/m or greater at a distance of 3 meters. During regular monitoring,
any leakage source which produces a field strength of 20 uV/m or
greater at a distance of 3 meters in the aeronautical radio frequency
bands shall be noted and such leakage sources shall be repaired within
a reasonable period of time.
Note 1 to § 76.614: Section 76.1706 contains signal leakage
recordkeeping requirements applicable to cable operators.
[ 65 FR 53616 , Sept. 5, 2000]
Goto Section: 76.613 | 76.616
Goto Year: 2008 |
2010
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public