Goto Section: 15.105 | 15.109 | Table of Contents
FCC 15.107
Revised as of October 1, 2010
Goto Year:2009 |
2011
§ 15.107 Conducted limits.
(a) Except for Class A digital devices, for equipment that is designed
to be connected to the public utility (AC) power line, the radio
frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies within the band 150 kHz to 30 MHz shall not
exceed the limits in the following table, as measured using a 50 mH/50
ohms line impedance stabilization network (LISN). Compliance with the
provisions of this paragraph shall be based on the measurement of the
radio frequency voltage between each power line and ground at the power
terminal. The lower limit applies at the band edges.
Frequency of emission (MHz) Conducted limit (dBmV)
Quasi-peak Average
0.15-0.5 66 to 56* 56 to 46*
0.5-5 56 46
5-30 60 50
*Decreases with the logarithm of the frequency.
(b) For a Class A digital device that is designed to be connected to
the public utility (AC) power line, the radio frequency voltage that is
conducted back onto the AC power line on any frequency or frequencies
within the band 150 kHz to 30 MHz shall not exceed the limits in the
following table, as measured using a 50 mH/50 ohms LISN. Compliance
with the provisions of this paragraph shall be based on the measurement
of the radio frequency voltage between each power line and ground at
the power terminal. The lower limit applies at the boundary between the
frequency ranges.
Frequency of emission (MHz) Conducted limit (dBmV)
Quasi-peak Average
0.15-0.5 79 66
0.5-30 73 60
(c) The limits shown in paragraphs (a) and (b) of this section shall
not apply to carrier current systems operating as unintentional
radiators on frequencies below 30 MHz. In lieu thereof, these carrier
current systems shall be subject to the following standards:
(1) For carrier current systems containing their fundamental emission
within the frequency band 535-1705 kHz and intended to be received
using a standard AM broadcast receiver: no limit on conducted
emissions.
(2) For all other carrier current systems: 1000 mV within the frequency
band 535-1705 kHz, as measured using a 50 mH/50 ohms LISN.
(3) Carrier current systems operating below 30 MHz are also subject to
the radiated emission limits in § 15.109(e).
(d) Measurements to demonstrate compliance with the conducted limits
are not required for devices which only employ battery power for
operation and which do not operate from the AC power lines or contain
provisions for operation while connected to the AC power lines. Devices
that include, or make provision for, the use of battery chargers which
permit operating while charging, AC adaptors or battery eliminators or
that connect to the AC power lines indirectly, obtaining their power
through another device which is connected to the AC power lines, shall
be tested to demonstrate compliance with the conducted limits.
[ 54 FR 17714 , Apr. 25, 1989, as amended at 57 FR 33448 , July 29, 1992;
58 FR 51249 , Oct. 1, 1993; 66 FR 19098 , Apr. 13, 2001; 67 FR 45670 ,
July 10, 2002]
Goto Section: 15.105 | 15.109
Goto Year: 2009 |
2011
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public