Goto Section: 15.113 | 15.117 | Table of Contents
FCC 15.115
Revised as of October 1, 2014
Goto Year:2013 |
2015
§ 15.115 TV interface devices, including cable system terminal devices.
(a) Measurements of the radiated emissions of a TV interface device
shall be conducted with the output terminal(s) of the device terminated
by a resistance equal to the rated output impedance. The emanations of
a TV interface device incorporating an intentional radiator shall not
exceed the limits in § 15.109 or subpart C of this part, whichever is
higher for each frequency. Where it is possible to determine which
portion of the device is contributing a particular radio frequency
emission, the emissions from the TV interface device portion shall
comply with the emission limits in § 15.109, and the emissions from the
intentional radiator shall comply with subpart C of this part.
(b) Output signal limits:
(1) At any RF output terminal, the maximum measured RMS voltage, in
microvolts, corresponding to the peak envelope power of the modulated
signal during maximum amplitude peaks across a resistance (R in ohms)
matching the rated output impedance of the TV interface device, shall
not exceed the following:
(i) For a cable system terminal device or a TV interface device used
with a master antenna, 692.8 times the square root of (R) for the video
signal and 155 times the square root of (R) for the audio signal.
(ii) For all other TV interface devices, 346.4 times the square root of
(R) for the video signal and 77.5 times the square root of (R) for the
audio signal.
(2) At any RF output terminal, the maximum measured RMS voltage, in
microvolts, corresponding to the peak envelope power of the modulated
signal during maximum amplitude peaks across a resistance (R in ohms)
matching the rated output impedance of the TV interface device, of any
emission appearing on frequencies removed by more than 4.6 MHz below or
7.4 MHz above the video carrier frequency on which the TV interface
device is operated shall not exceed the following:
(i) For a cable system terminal device or a TV interface device used
with a master antenna, 692.8 times the square root of (R).
(ii) For all other TV interface devices, 10.95 times the square root of
(R).
(3) The term master antenna used in this section refers to TV interface
devices employed for central distribution of television or other video
signals within a building. Such TV interface devices must be designed
to:
(i) Distribute multiple television signals at the same time;
(ii) Distribute such signals by cable to outlets or TV receivers in
multiple rooms in the building in which the TV interface devices are
installed; and,
(iii) Distribute all over-the-air or cable signals.
Note: Cable-ready video cassette recorders continue to be subject to
the provisions for general TV interface devices.
(c) A TV interface device shall be equipped with a transfer switch for
connecting the antenna terminals of a receiver selectively either to
the receiving antenna or to the radio frequency output of the TV
interface device, subject to the following:
(1) When measured in any of its set positions, transfer switches shall
comply with the following requirements:
(i) For a cable system terminal device or a TV interface device
equipped for use with a cable system or a master antenna, as defined in
paragraph (b)(3) of this section, the isolation between the antenna and
cable input terminals shall be at least 80 dB from 54 MHz to 216 MHz,
at least 60 dB from 216 MHz to 550 MHz and at least 55 dB from 550 MHz
to 806 MHz. The 80 dB standard applies at 216 MHz and the 60 dB
standard applies at 550 MHz. In the case of a transfer switch requiring
a power source, the required isolation shall be maintained in the event
the device is not connected to a power source or power is interrupted.
(ii) For all other TV interface devices, the maximum voltage,
corresponding to the peak envelope power of the modulated video signal
during maximum amplitude peaks, in microvolts, appearing at the
receiving antenna input terminals when terminated with a resistance (R
in ohms) matching the rated impedance of the antenna input of the
switch, shall not exceed 0.346 times the square root of (R).
(iii) Measurement to determine compliance with the transfer switch
limits shall be made using a connecting cable, where required, between
the TV interface device and the transfer switch of the type and length:
(A) Provided with the TV interface device,
(B) Recommended in the instruction manual, or
(C) Normally employed by the consumer.
(2) A TV interface device shall be designed and constructed, to the
extent practicable, so as to preclude the possibility that the consumer
may inadvertently attach the output of the device to the receiving
antenna, if any, without first going through the transfer switch.
(3) A transfer switch is not required for a TV interface device that,
when connected, results in the user no longer having any need to
receive standard over-the-air broadcast signals via a separate antenna.
A transfer switch is not required to be marketed with a cable system
terminal device unless that device provides for the connection of an
external antenna. A transfer switch is not required for a device that
is intended to be used as an accessory to an authorized TV interface
device.
(4) An actual transfer switch is not required for a TV interface
device, including a cable system terminal device, that has an antenna
input terminal(s); provided, the circuitry following the antenna input
terminal(s) has sufficient bandwidth to allow the reception of all TV
broadcast channels authorized under part 73 of this chapter and: For a
cable system terminal device that can alternate between the reception
of cable television service and an antenna, compliance with the
isolation requirement specified in paragraph (c)(1)(i) of this section
can be demonstrated; and, for all other TV interface devices, the
maximum voltage appearing at the antenna terminal(s) does not exceed
the limit in paragraph (c)(1)(ii) of this section.
(5) If a transfer switch is not required, the following label shall be
used in addition to the label shown in § 15.19(a):
This device is intended to be attached to a receiver that is not used
to receive over-the-air broadcast signals. Connection of this device in
any other fashion may cause harmful interference to radio
communications and is in violation of the FCC Rules, part 15.
(d) A TV interface device, including a cable system terminal device,
shall incorporate circuitry to automatically prevent emanations from
the device from exceeding the technical specifications in this part.
These circuits shall be adequate to accomplish their functions when the
TV interface device is presented, if applicable, with video input
signal levels in the range of one to five volts; this requirement is
not applicable to a TV interface device that uses a built-in signal
source and has no provisions for the connection of an external signal
source. For devices that contain provisions for an external signal
source but do not contain provisions for the input of an external
baseband signal, e.g., some cable system terminal devices, compliance
with the provisions of this paragraph shall be demonstrated with a
radio frequency input signal of 0 to 25 dBmV.
(e) For cable system terminal devices and TV interface devices used
with a master antenna, as defined in paragraph (b)(3) of this section,
the holder of the grant of authorization shall specify in the
instruction manual or pamphlet, if a manual is not provided, the types
of wires or coaxial cables necessary to ensure that the unit complies
with the requirements of this part. The holder of the grant of
authorization must comply with the provisions of § 15.27. For all other
TV interface devices, the wires or coaxial cables used to couple the
output signals to the TV receiver shall be provided by the responsible
party.
(f) A TV interface device which is submitted to the Commission as a
composite device in a single enclosure containing a RF modulator, video
source and other component devices shall be submitted on a single
application (FCC Form 731) and shall be authorized as a single device.
(g) An external device or accessory that is intended to be attached to
a TV interface device shall comply with the technical and
administrative requirements set out in the rules under which it
operates. For example, a personal computer must be certificated to show
compliance with the regulations for digital devices.
(h) Stand-alone switches used to alternate between cable service and an
antenna shall provide isolation between the antenna and cable input
terminals that is at least 80 dB from 54 MHz to 216 MHz, at least 60 dB
from 216 MHz to 550 MHz and at least 55 dB from 550 MHz to 806 MHz. The
80 dB standard applies at 216 MHz and the 60 dB standard applies at 550
MHz. In the case of stand-alone switches requiring a power source, the
required isolation shall be maintained in the event the device is not
connected to a power source or power is interrupted.
(i) Switches and other devices intended to be used to by-pass the
processing circuitry of a cable system terminal device, whether
internal to such a terminal device or a stand-alone unit, shall not
attenuate the input signal more than 6 dB from 54 MHz to 550 MHz, or
more than 8 dB from 550 MHz to 804 MHz. The 6 dB standard applies at
550 MHz.
[ 54 FR 17714 , Apr. 25, 1989, as amended at 57 FR 33448 , July 29, 1992;
59 FR 25341 , May 16, 1994; 61 FR 18509 , Apr. 26, 1996; 77 FR 4913 , Feb.
1, 2012]
return arrow Back to Top
Goto Section: 15.113 | 15.117
Goto Year: 2013 |
2015
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public