Goto Section: 73.154 | 73.157 | Table of Contents
FCC 73.155
Revised as of October 2, 2015
Goto Year:2014 |
2016
§ 73.155 Periodic directional antenna performance recertification.
A station licensed with a directional antenna pattern pursuant to a proof of
performance using moment method modeling and internal array parameters as
described in § 73.151(c) shall recertify the performance of that directional
antenna pattern at least once within every 24 month period.
(a) Measurements shall be made to verify the continuing integrity of the
antenna monitor sampling system.
(1) For towers using base current or base voltage sampling derived at the
output of the antenna coupling and matching equipment, the sampling devices
shall be disconnected and calibrated by measuring their outputs with a
common reference signal (a current through them or a voltage across them, as
appropriate) and the calibration must agree with the manufacturer's
specifications.
(2) For towers using base current or base voltage sampling derived at the
output of the antenna coupling and matching equipment, sampling line
measurements shall be made to verify the open-circuit resonant frequency
closest to carrier frequency, to establish length, and also at frequencies
corresponding to odd multiples of 1⁄8 wavelength immediately above and below
the open-circuit resonant frequency closest to carrier frequency, while open
circuited, to verify their characteristic impedance. The frequencies
measured must be the same as were measured in the most recent proof of
performance and must demonstrate that the sampling lines continue to meet
the requirements of § 73.151(c) with regard to their length and
characteristic impedance.
(3) For towers having sampling loops, measurements shall be made at carrier
frequency or, if necessary, at nearby frequencies where the magnitude of the
measured impedance is no greater than 200 ohms with the sampling loops
connected. The frequencies measured must be the same as were measured in the
most recent proof of performance and the measured impedances must agree
within ±2 ohms and ±4 percent resistance and reactance of the proof values.
(b) Field strength measurements shall be made at the reference field
strength measurement locations that were established by the most recent
proof of performance. If locations have become inaccessible or their
readings contaminated by localized electromagnetic environmental changes,
new locations that meet the requirements of the moment method proof of
performance rules in § 73.151(c)(3) shall be established to replace them.
(c) The results of the periodic directional antenna performance
recertification measurements shall be retained in the station's public
inspection file.
[ 73 FR 64562 , Oct. 30, 2008]
return arrow Back to Top
Goto Section: 73.154 | 73.157
Goto Year: 2014 |
2016
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public